TM44 Air Conditioning Inspection

About this service

What is a TM44 air conditioning inspection?

A TM44 inspection is a mandatory energy assessment of air conditioning systems with an effective rated output above 12 kW, carried out to the methodology in CIBSE TM44. It is required by the Energy Performance of Buildings (England and Wales) Regulations 2012, which implement Article 15 of the EPBD. The 12 kW threshold is the combined output of all coupled units serving a single building under one person's control, not per individual unit.

Every commercial building with qualifying air conditioning needs a first inspection within five years of installation, and a repeat inspection at least every five years thereafter. The duty falls on the person who controls the operation of the system, which is usually the building owner, occupier or facilities manager. Systems serving multiple tenants are typically the landlord's responsibility under the lease.

The deliverable is a TM44 report listing every indoor and outdoor unit, its condition, controls, sizing relative to load, and recommendations to reduce energy use. The report is lodged on the Landmark non-domestic register and a copy must be kept on site, available for inspection. Recommendations are advisory, but the inspection itself is not optional.

Why this matters: Failure to commission a TM44 inspection on a qualifying air conditioning system carries a £300 fixed penalty per building under the EPB Regulations 2012, with a further £200 for not producing the report on request, and Trading Standards can re-issue penalties for continuing breaches.

Recent work

Recent TM44 Air-Con Inspection jobs

Outdoor Mitsubishi condensersBakery, North London
Indoor split + controllerCommercial kitchen
Mitsubishi ceiling cassetteRetail ceiling install
Dimplex air curtainsShopfront entrance

Who needs one

You probably need this if...

  • Offices with VRF or split systems over 12 kW combined
  • Retail units with substantial cooling plant
  • Restaurants and kitchens with comfort cooling
  • Data centres and server rooms with dedicated cooling
  • Hotels, gyms and leisure facilities
  • Any commercial site five years since last TM44

How Axe Energy works

1

Get an instant quote

Pick your service, enter your floor area, and see a fixed price in 60 seconds. Or call 07429 040520.

2

Book in seconds

Pay securely online or over the phone. We confirm your slot the same day, often within the hour.

3

Certified in 48 hours

We'll contact you to schedule our visit, then complete your order as soon as possible.

Why choose us?

From booking to lodgement, we make commercial energy compliance the easiest job on your list.

  • Fully accredited assessors
  • Next day appointments
  • Fixed pricing — pay on completion
  • Rated 5.0 on Google
Learn more

Rated 5.0 on

Over 1,000 commercial EPCs delivered across London. Read what landlords, agents, and facilities managers say about working with us.

★★★★★

Highly efficient dealing with Ricky. He came early, informed me correctly of my unit's size (it was larger than I thought!). He also turned the certificate around in under 24 hours.

Paradise Cove

Battersea

★★★★★

Mr Ricky Kamboj recently visited our premises for EPC. Great service, very polite. Definitely recommend. Nicely explained and quick respond.

Dry Cleaners Kenton

North-West London

★★★★★

Very professional and efficient service. Kept me fully appraised and delivered ahead of expectations.

Julian Curtis

Verified Google review

Accredited By

ECMK
Elmhurst Energy
Quidos
City & Guilds

Regulated by

  • CIBSE TM44
  • EPB Regulations 2012
  • Article 15 EPBD
  • Landmark register

Frequently Asked Questions

It is the total effective rated cooling output of all air conditioning units within a single building under one operator's control, added together. A building with six 3 kW splits (18 kW total) needs an inspection; a building with a single 10 kW unit does not. Refrigeration and process cooling are excluded.